Open a web browser and enter "10.10.100.254" into the address bar 4. In order to to set an IP address you can use a Mobile Phone, Tablet or Computer. No-Grid - El inversor no reconoce la red. Go to your web browser - Input 10.10.100.254 4. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. SolisCloud is the new generation of intelligent PV system monitoring. In general you want to ensure the router is not blocking the IP address from the WIFI stick. If the WIFI stick doesn't show a connected inverter check the address of the inverter. If the connection is weak (1-2 bars) then it is recommended to install aWiFirange extender to boost the signal strength where the logger is going to be. If it has a good connection to the inverter do the following steps: 1. Let us know how can we improve this article! Open the Local Connection Status, clickon Properties, select internet protocol IPv4(TCP/IPv4). Interaction, Climate Change, Sustainability & Connect your laptop to the Solis Wi-Fi network - this has a name which looks like "AP-xxxxxxxxx" 3. These limits are designed to provide reasonable protection against harmful interference in a residential installation. If you hate cookies, or are just on a diet, you can disable them altogether too. Internal DC Short: In the inverter head, or the wirebox? Or directly download from APP Store or Google Play Store by searching SolisCloud. Plug the provided charging cable into Skyroam Solis and connect to a power source. Start by opening yourWiFisettings and then connecting to the network that starts with "AP" - this is theWiFilogger's local network which allows you to link it to the home network. 4G Next COnfigurate Connection 15:30 Back Enter the plant name Done Plant Name Verify the RSSI (signal strength) is higher than 15%. Then click Done. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. Router password is incorrect 3. solis SOL-DLS-W Data Logger Wifi Stick Introduction Data Logger Wifi Stick Is mainly used: 10 inverters 10 realize simple and Quick access to Internet. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . If you have not already been registered onSolisCloud, please see Step 18:SolisCloudMonitoring Platform. If its not either move the inverter closer to the router, the router closer to the inverter or use a repeater to boost the strength. You can select the corresponding server information according to the model of data logger used by the plant. Connect to the datalogger - AP_XXXXXXXXXX, 3. Did you find it helpful? Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. Connect to the inverter (to get power) 3. We use cookies to try and give you a better experience in Freshdesk. Ginlong Solis(Stock Code: 300763.SZ) is one of the oldest and largest global string inverter specialists, that manufactures string inverters for converting DC to AC power and interacting with utility grid, which help reduce the carbon footprint of human s If failed, re-do the configuration process or contact the after-sale engineers. Connect one end of an ethernet cable to LAN stick, 2: On the computer, click on the Network Connections and select the Local Connection. We use cookies to try and give you a better experience in Freshdesk. Did you get a response from Ginlong? If there are symbols in the password, it must be changed or the logger will not connect to it. it has come back on line, so it is obviously a connection issue, Xi Jinping must have forgot to reboot the GFW this morning, Copyright 2000- 2023 Boards Software Limited, If you have a new account but are having problems posting or verifying your account, please email us on, Hello All, This is just a friendly reminder to read the Forum Charter where you wish to post before posting in it. 1: Connect LAN stick to operational inverter to provide power to LAN stick. No-Grid - El inversor no reconoce la red. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals) 2. 1. 5. Step 2: If it is a new data logger, please configure it first, then click the Willi configure. ContactPlease contact us if you have any technical problems in terms of the product. It came with a Ginlong data logger wifi stick that I have set up according to the instructions. The communication topology is as shown below: Description of Symbols If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. If the plant has multiple data loggers, please click View Plant. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help. Intro Inverter Logger Device Connect Summary Device Make Sure Phone Connected to WiFi Network Please Make Sure Phone Connected to WiFi then Click Next 15:38 Back Connect WiFi SN: 4005854756 Enter Netwo. Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. (DLB-W(Wifi),Lan Data Logger, Wifi Data Logger,S3-WIFI-ST,Celluar Data Logger,1500V PLC CCO, Solis-ATR-6K), For the duration of this period Ginlong guarantees the proper functions of the Products. No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals), 4. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. Connect to the datalogger - AP_XXXXXXXXXX 3. This process can also be used to move a Solis Data Logger from one site to another. Or directly download from APP Store or Google Play Store by searching "SolisCloud". My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. Solis Data Loggers. It may also be affected by lighting storms. Administrators, Computer Games Moderators, Sports Moderators, https://www.boards.ie/discussion/comment/118925467#Comment_118925467, https://www.boards.ie/discussion/comment/118925665#Comment_118925665, https://www.boards.ie/discussion/2058241657/solis-app-gone-off-line, https://www.boards.ie/discussion/comment/118926624#Comment_118926624, Music Production Commercial You should see a message that says "Bound Successfully" and now you will need to set up the logger on the localWiFinetwork. View real-time data of the PV plant , and get equipment condition is controlled at anytime and anywhere. Solarman Data Loggers (4-pin only) DLS-W: WiFi only data logger; DLS-L: LAN only data logger; DLS-C: 4G cellular only data logger; Solis is no longer selling these products in the US; Our distributors likely still have stock of these products but we are not promoting them; Solarman loggers do not support remote settings changes or firmware updates